Always use Thistlebond CLEAN AID to wipe re-blasted surfaces before applying Advanced Polymer Thistlebond PRODUCTS.
This will also be the case if you have to RE-PREPARE a previously coated surface that has cured.

When applying TWO coats, the second coat is applied when the first coat is TACKY to the touch. If the first coat has cured then BRUSH BLAST and use CLEAN AID as above.

Gloves should be worn in all applications to avoid product on hands as well as to preventive grease from unprotected hands getting in contact with the coating material.

Every effort should be made to apply the first coat within 1 hour (as soon as possible) after wiping with CLEAN AID - this to prevent flash rusting on metal equipment.

ups logo
EXCEPTION to second coat onto WET surface is Thistlebond ELASTIC MEMBRANE. The SECOND and any subsequent coats are applied onto a DRY surface.

Care should be taken when planning the application to ensure that timing is relevant to your working conditions as well as POT LIFE of the product being used.

ALL INFORMATION IN DETAIL is supplied on the Advanced Polymer ENGINEERING and APPLICATION DATA SHEETS. Please see TECHNICAL INFORMATION DOWNLOADS.

Recommended product thickness - number of coats recommended and coverage per packaged unit are available form the above detailed sheets that will accompany your product. Please consult with your Advanced Polymer sales specialist / application engineer for further information.

Thickness Measurements

1 Inch = 1000 mils = 25.4 mm

1 mil = 25 microns

4 mils = 100 microns = 0.1 mm

8 mils = 200 microns = 0.2 mm

16 mils = 400 microns = 0.4 mm

1/16" = 62.5 mils = 1.6 mm

1/8" = 125 mils = 3.2 mm

1/4" = 250 mils = 6.35 mm

hr02

Fitness For Purpose Joint Design Surface Preparation Product Mixing
Application Curing Service Conditions Inspection / Touch Up